Specifications
|
Measurement range |
Water (20℃) (1 to 200000) L/h Air (20℃, 0.1013MPa) (0.03 to 3000) m³/h |
|
Range ratio |
Standard type 10:1, special type 20:1 |
|
Accuracy |
Standard type 1.5 grade, special type 1.0 grade, gas type 1.5 grade |
|
Pressure |
Standard type: DN15 to DN50 ≤ 4.0MPa, DN80 to DN200 ≤ 1.6MPa Special type: DN15 to DN50 ≤ 32MPa, DN80 to DN200 ≤ 16MPa The pressure rating of the jacket is 1.6MPa. |
|
Process connection |
Flange type, sanitary clamp type, standard thread type, sanitary thread type, special type, as per user requirements or provided by user. |
|
Clip connection |
Standard type: Flange connection HG20592 DN15/PN1.6MPa |
|
Medium temperature |
Standard type: -20℃ to +120℃; PTFE: 0℃ to 80℃; High temperature type: 120℃ to 450℃ (explosion-proof type 400℃); Low temperature type: -196℃ to -20℃ |
|
Ambient temperature |
Remote transmission type: -30℃ to +80℃; Local pointer type: -40℃ to +100℃; Intrinsically safe and explosion-proof type: -40℃ to +60℃ |
|
Cable connector |
M20*1.5 internal thread and M16*1.5 internal thread are available with optional aviation connectors. |
|
Power supply |
Standard type: 24VDC two-wire (4 to 20)mA (12VDC to 32VDC) Alarm type: 24VDC multi-wire (4 to 20)mA (12VDC to 32VDC) AC type: (100 to 240)VAC 50Hz to 60Hz Battery type: 3.6V@9AH lithium battery, can be used continuously for three years |
|
Load characteristics |
RLmax=600Ω Intrinsically safe type: 500Ω |
|
Alarm output |
Instantaneous flow alarm with upper and lower limits, optocoupler signal isolation Darlington transistor output (internal 24VDC power supply, maximum current 8mA, external power supply 250mA@36VDC). Local alarm type: upper and lower limit or upper and lower limit instantaneous flow alarm. Reed switch alarm (contact capacity 1A@30VDC), selectable open/normally closed. Maximum range of 60% for upper and lower limit alarms, minimum interval of 10% for upper and lower limit alarms. |
|
Pulse output |
The accumulated pulse output is an optocoupler-isolated Darlington transistor output (internal 24VDC, maximum current 8mA). |
|
Protection Class |
IP65 |
|
Explosion-proof Class |
Intrinsically safe type: Exia II CT2~T6 Gb Explosion-proof type: Exd II CT6 Gb |
|
Intrinsic safety parameters |
Ui≤28V li≤100mA Pi≤0.7W Ci≤0.021μF Li≈0mH |
|
Instrument installation height |
The center dimension of the DN10 threaded installation is 125mm. The vertical height of the standard DN15 to 200 type is 250mm. The height of the high-pressure type instrument with a pressure greater than 6.3MPa to 10MPa and a diameter greater than or equal to DN80 is 300mm. |
|
medium viscosity |
DN15:η<5mPa.s(S15.0~S15.3)η<30mPa.s(S15.4~S15.10) DN25:η<250mPa.s DN50~DN200:η<300mPa.s |
|
Diameter |
Flow segment float code |
Water(L/h) |
Air |
Table of pressure loss for different structures (kPa) |
||||||
|
Material 304 316L Ti Hc |
Material PTFE |
m³/h(20℃ latm) |
Standard |
Downward in, upward horizontal out |
Downward horizontal stroke in; upward horizontal stroke out |
Left in, right out; Right in, left out |
Horizontal spring |
Upward and downward |
||
|
DN15 |
0 |
10 |
0.3 |
6.8 |
10.8 |
16.8 |
22.8 |
|||
|
1 |
16 |
0.5 |
6.8 |
10.8 |
16.8 |
22.8 |
||||
|
2 |
14 |
16 |
0.7 |
6.8 |
10.8 |
16.8 |
22.8 |
16 |
14 |
|
|
3 |
40 |
25 |
1.2 |
6.8 |
10.8 |
16.8 |
22.8 |
19.5 |
17.8 |
|
|
4 |
63 |
40 |
1.8 |
7 |
11 |
17 |
23 |
20.4 |
18 |
|
|
5 |
100 |
60 |
3 |
7.2 |
11.2 |
17.2 |
23.2 |
|||
|
6 |
160 |
100 |
4.8 |
7.8 |
11.8 |
17.8 |
23.8 |
22.5 |
20 |
|
|
7 |
250 |
160 |
7 |
9 |
13 |
19 |
25 |
25 |
22 |
|
|
8 |
400 |
250 |
12 |
12 |
16 |
22 |
28 |
32.5 |
29 |
|
|
9 |
630 |
400 |
18 |
13 |
17 |
23 |
29 |
45 |
41 |
|
|
10 |
1000 |
30 |
16 |
20 |
26 |
32 |
59 |
50 |
||
|
DN25 |
0 |
300 |
14 |
3.8 |
7.8 |
13.8 |
19.8 |
|||
|
1 |
630 |
400 |
21 |
3.8 |
7.8 |
13.8 |
19.8 |
|||
|
2 |
1000 |
630 |
30 |
4.2 |
8.2 |
14.2 |
20.2 |
11 |
9.7 |
|
|
3 |
1600 |
1000 |
48 |
5.7 |
9.7 |
15.7 |
21.7 |
11 |
9.7 |
|
|
4 |
2500 |
1600 |
70 |
6 |
10 |
16 |
22 |
12 |
10.5 |
|
|
5 |
3200 |
100 |
6.6 |
10.6 |
16.6 |
22.6 |
12 |
10.5 |
||
|
6 |
4000 |
2000 |
130 |
7.8 |
11.8 |
17.8 |
23.8 |
14.5 |
11.5 |
|
|
7 |
5000 |
2500 |
150 |
8.8 |
12.8 |
18.8 |
24.8 |
14.5 |
11.5 |
|
|
8 |
6300 |
3200 |
180 |
10.3 |
14.3 |
20.3 |
26.3 |
21.7 |
17.2 |
|
|
9 |
10000 |
16 |
20 |
26 |
32 |
24 |
19.5 |
|||
|
DN50 |
0 |
4000 |
130 |
4.2 |
8.2 |
14.2 |
20.2 |
|||
|
1 |
6300 |
4000 |
180 |
4.7 |
8.7 |
14.7 |
20.7 |
24 |
22 |
|
|
2 |
10000 |
6300 |
300 |
6 |
10 |
16 |
22 |
24 |
22 |
|
|
3 |
16000 |
10000 |
500 |
6 |
10 |
16 |
22 |
24 |
22 |
|
|
4 |
20000 |
16000 |
600 |
6.5 |
10.5 |
16.5 |
22.5 |
30 |
26 |
|
|
5 |
25000 |
700 |
7 |
11 |
17 |
23 |
42 |
40 |
||
|
DN80 |
0 |
10000 |
6 |
10 |
16 |
22 |
13 |
11 |
||
|
1 |
16000 |
500 |
6.8 |
10.8 |
16.8 |
22.8 |
16 |
14.5 |
||
|
2 |
25000 |
16000 |
700 |
7 |
11 |
17 |
23 |
18 |
15 |
|
|
3 |
40000 |
25000 |
1200 |
13 |
17 |
23 |
29 |
23 |
21 |
|
|
4 |
63000 |
40000 |
1800 |
15 |
19 |
25 |
31 |
32 |
29 |
|
|
DN100 |
0 |
40000 |
1200 |
6.5 |
10.5 |
16.5 |
22.5 |
24 |
26 |
|
|
1 |
63000 |
40000 |
1800 |
6.5 |
10.5 |
16.5 |
22.5 |
25 |
27 |
|
|
2 |
80000 |
60000 |
2500 |
20 |
24 |
30 |
36 |
26 |
31.5 |
|
|
3 |
100000 |
3000 |
22 |
26 |
32 |
38 |
30 |
38 |
||
|
DN150 |
0 |
80000 |
2500 |
22 |
26 |
32 |
38 |
35 |
41 |
|
|
1 |
100000 |
3000 |
50 |
54 |
55 |
60 |
55 |
56 |
||
|
2 |
150000 |
60 |
58 |
58 |
62 |
60 |
60 |
|||
|
DN200 |
0 |
150000 |
*Special type |
50 |
54 |
60 |
66 |
65 |
61 |
|
|
1 |
200000 |
70 |
80 |
80 |
85 |
70 |
70 |
|||
Features
1. Utilizes multi-segment conical tube technology, making the dial more linear.
2. Dual indicating system to meet the needs of users in different working conditions.
3. The panel uses an aluminum dial with a long pointer mechanical indicator, resulting in a more aesthetically pleasing panel. It features a low-power, full-view, dual-line backlit LCD digital display that can simultaneously display instantaneous flow, cumulative flow, and corresponding delays.
4. Equipped with a magnetic damping system to effectively reduce pointer jitter.
5. Added a geomagnetic interference compensation device to effectively overcome the influence of the geomagnetic field on the instrument.
6. Suitable for measuring small flow rates of various media.
7. Simple structure and easy installation.
How It Works
The product mainly consists of two parts: a measuring tube and an indicator. The measuring tube includes components such as a conical tube or orifice plate, a guide, a stopper, and a float, while the indicator includes components such as a magnetic follower system, a graduated needle, a dial, and a circuit board (for remote transmission).
When the measured medium flows from bottom to top through the measuring tube, a pressure difference is generated at the upper and lower ends of the float, creating an upward force. When the upward force on the float is greater than the weight of the float immersed in the fluid, the float rises, the annular gap area increases accordingly, the flow velocity in the annular gap decreases rapidly, the pressure difference between the upper and lower ends of the float decreases, and the upward force acting on the float decreases accordingly until the upward force is balanced with the weight of the float immersed in the fluid. At this point, the float stabilizes at a certain position, and the height of the float position corresponds to the flow rate of the measured medium.
The float has a built-in magnet, and the magnetic field changes as the float moves up and down with the medium. The follower magnet fixed on the pointer shaft in the indicator is coupled to the magnet inside the float, which drives the pointer and the sensing magnet to rotate. The local instantaneous flow indicated by the pointer on the dial is converted into an electrical signal by the magnetic sensor, and after being processed by the circuit, the instantaneous flow and the cumulative flow are displayed.
Applications
Metal tube float flowmeters are a commonly used variable area flow meter in industrial automation control. They are characterized by their small size, wide detection range, and ease of use. They can be used to measure the flow rate of liquids, gases, and steam, and are particularly suitable for measuring the flow rate of low-velocity, low-flow, high-temperature, high-pressure, highly corrosive, conductive, or non-conductive media.
This series of metal tube float flowmeters conforms to the national standard JB/T 6844-2015, and its factory verification conforms to the verification JJG257-2007.
This product has been inspected and approved by a nationally designated explosion-proof quality inspection agency and meets the relevant requirements of GB3836.1-2010, GB3836.2-2010, GB3836.4-2010, and GB3836.20-2010 standards. Its explosion-proof markings are: Flameproof Exd II CT2-T6Gb, Intrinsically safe Exia II CT6 Gb.
Hot Tags: metal tube float flowmeter, China metal tube float flowmeter manufacturers, suppliers, factory, Electromagnetic Flowmeter, Vortex Flowmeter, flow measurement