Magnetic Flow Meter

Magnetic Flow Meter
Details:
Line Size: ½-36 inch (15-900 mm)
Liner Material: PTFE, ETFE, PFA, Polyurethane, Neoprene, Linatex Natural Rubber
Electrode Material: 316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium
Accuracy: Standard ±0.5%; Optional ±0.2%
Signal output: 4-20mA HART;Modbus RS485; relay output
Send Inquiry
Introduction
Technical Data
Features
Product Applications

Product Guarantees        FAQ

Introduction

 

Our industrial magnetic flow meter delivers reliable, obstruction-free volumetric flow measurement for conductive liquids across water, wastewater, chemical processing, and utility applications. Built on Faraday's law of electromagnetic induction, this sensor contains no moving parts and introduces zero pressure loss, making it ideal for continuous process monitoring, custody transfer, and effluent discharge compliance.

With a line size range from ½" to 36" (15-900 mm), the meter supports a wide selection of liner materials - including PTFE, PFA, ETFE, polyurethane, neoprene, and Linatex natural rubber - paired with electrode options in 316L stainless steel, nickel alloy, platinum, tantalum, and titanium. This modular configuration allows precise material matching to corrosive, abrasive, or high-temperature process media up to 180°C (356°F).

Standard accuracy is ±0.5% of reading; an optional ±0.2% flat-spec calibration is available for higher-accuracy requirements. The integrated transmitter outputs 4–20mA with HART protocol, Modbus RS485, and relay outputs, enabling seamless integration with DCS, PLC, and SCADA systems. Rated IP67 and certified for process pressures up to PN40 / Class 300, the meter is engineered for long-term stability in both indoor and outdoor industrial environments.

 

Technical Data

 

Below are detailed technical parameters covering size ranges, material options, performance ratings, electrical outputs and environmental ratings. Contact our technical sales team if you require a custom configuration for specific operating conditions.

 

Diameter range

DN15 to 600 (1/2 to 24")

Measured variables

volume flow, conductivity, mass flow

Accuracy

Volume flow(standard): ±0.5% or ±1mm/s (0.04 in/s)

Volume flow (option): ±0.2 % or ±2 mm/s (0.08 in/s), Flat Spec

Measuring range

4dm3/min to 9600 m3/h (1 gal/min to 44000 gal/min)

Medium temperature range

Liner material PFA: -20 to +150℃ (-4 to +302 ℉)

Liner material PFA high temperature:-20 to +180℃ (-4 to 356℉)

Liner material PTFE: -40 to +130℃ (-40 to +266℉)

Ambient temperature range

Flange material carbon steel: -10 to +60℃ (+14 to +140℉)

Flange material stainless steel: -40 to +60℃ (-40 to +140℉)

Sensor housing material

DN15 to 300(1/2 to 12"): AISi 10Mg, coated

DN350 to 600(14 to 24"): Carbon steel

Transmitter housing material

AISi10Mg, coated; 316L; stainless steel for hygenic transmitter design

Protection class

IP67

Display/operation

4-line backlit display with touch control; Remote display

Signal output

4-20mA HART; 4-20mA WirelessHART; Modbus RS485; relay output

Inputs

4-20mA input

Power supply

DC24V; AC100 to 230V; AC100 to 230V/DC 24V

Maximum process pressure

PN40, Class 300, 20K

Line Size

½-36 inch (15-900 mm)

Liner Materials

PTFE, ETFE, PFA, Polyurethane, Neoprene, Linatex Natural Rubber

Electrode Materials

316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium

Flange Ratings

ASME B16.5 Class 150-2500DIN PN 10-40AS 2129 Table D and EAWWA C207 Table 3 Class D (30-36 inch only)

 

Magnetic Flow Meter

 

Features

 

1. Wide Size Range & Flexible Configuration

Line sizes from ½" to 36" (DN15–DN900) to cover small process lines and large municipal mains

Modular sensor and transmitter design supports remote mount and integral mount installations

Multiple flange standards available: ASME B16.5 Class 150–2500, DIN PN 10–40, AS 2129, AWWA C207

2. Broad Material Compatibility for Harsh Media

Liner options: PTFE, PFA, ETFE, polyurethane, neoprene, and Linatex natural rubber to handle corrosion, abrasion, and high temperatures

Electrode options: 316L stainless steel, nickel alloy, platinum, tantalum, and titanium for optimal chemical resistance

Medium temperature capability up to 180°C (356°F) with high-temperature PFA liner

3. High-Accuracy Measurement Performance

Standard accuracy: ±0.5% of reading or ±1 mm/s, whichever is greater

Optional high-accuracy calibration: ±0.2% of reading (flat spec) for custody transfer and billing applications

Wide measuring range from 4 dm³/min to 9600 m³/h (1 gpm to 44,000 gpm) with excellent turndown ratio

Measures volume flow, conductivity, and calculated mass flow from a single sensor body

4. No Moving Parts, Zero Pressure Loss

Obstruction-free full-bore design eliminates pressure drop and energy loss

No impellers, bearings, or seals to wear out - minimal maintenance over long service life

Tolerates suspended solids, sludge, and fibrous media without clogging

5. Industrial-Grade Communication & Outputs

4–20mA analog output with HART protocol for configuration and diagnostics

Modbus RS485 for multi-drop network integration and IIoT connectivity

Programmable relay outputs for alarm, batch control, and pulse totalization

Optional WirelessHART for cable-free installations

6. Robust Construction for Demanding Environments

IP67 ingress protection for outdoor and washdown locations

Sensor housings in coated aluminum alloy (DN15–DN300) or carbon steel (DN350–DN600)

Transmitter options in coated aluminum, 316L stainless steel, or hygienic stainless steel design

Process pressure ratings up to PN40, Class 300, and 20K

7. User-Friendly Operation & Diagnostics

4-line backlit display with touch control for local configuration and reading

Built-in empty pipe detection, electrode coating monitoring, and self-diagnostic functions

Reversible flow measurement with forward and reverse totalization

DC 24V, AC 100–230V, or dual AC/DC power supply options to match site conditions

 

Product Applications

 

This magnetic flow meter series is designed for conductive liquid flow measurement across municipal, industrial, and utility scenarios. With a wide line size range of ½"–36" (DN15–DN900) and configurable liner and electrode materials, it adapts to corrosive, abrasive, and high-temperature media where traditional mechanical meters fail.

  • Municipal Water & Wastewater Systems

Suitable for water supply mains, sewage lift stations, stormwater pipelines and effluent discharge monitoring. Rubber and polyurethane liners withstand sediment and debris, and IP67 housing supports outdoor and underground manhole installation. The wide size range covers both small branch lines and large-diameter trunk mains.

  • Chemical & Petrochemical Processing

Matches PTFE, PFA and high-performance electrode materials (tantalum, platinum, titanium) for strong acids, alkalis, corrosive solutions and solvent mixtures. It delivers stable measurement for batching, blending and process monitoring, with no moving parts to clog or corrode.

  • Industrial Effluent & Environmental Compliance

Provides traceable flow data for factory discharge outlets, supporting environmental reporting and regulatory compliance. Modbus RS485 and HART outputs enable seamless connection to SCADA systems for continuous data logging and remote monitoring.

  • Mining, Mineral Slurry & Aggregate Processing

Linatex natural rubber, neoprene and polyurethane liners resist abrasion from high-solid slurries, tailings and mine drainage. The full-bore obstruction-free design avoids blockages, making it ideal for heavy-duty slurry applications where turbine and vortex meters cannot operate reliably.

  • Power Plant & Industrial Utility Circuits

Used for cooling water, makeup water, chemical dosing and boiler feedwater measurement. Optional ±0.2% flat-spec calibration supports high-accuracy utility billing and energy efficiency calculation across variable flow rates.

  • Food, Beverage & Hygienic Auxiliary Processes

Hygienic 316L stainless steel transmitter options are available for clean water, CIP cleaning fluids and liquid ingredient measurement. The non-intrusive sensor design avoids dead zones and supports routine cleaning procedures.

 

Product Guarantees

 

Backed by 20+ years of industrial instrument manufacturing experience, we back every magnetic flow meter with end-to-end quality control and full-cycle technical support to ensure long-term stable performance in real operating conditions.

  • Factory Calibration Consistency Guarantee

Each meter undergoes multi-point flow calibration on standard calibration rigs before delivery, with accuracy strictly matching published specifications. 

  • Material & Workmanship Quality Guarantee

All liner materials, electrodes, flanges and housings conform to the declared specifications. Each sensor passes hydrostatic pressure testing and air tightness inspection during production to eliminate process defects before delivery.

  • Application Matching Guarantee

Our technical sales team verifies your full operating conditions - medium properties, temperature, pressure, pipe size and installation layout - before formal quotation. If the meter fails to adapt to your working conditions due to our improper selection advice, we will provide a free adjustment or replacement solution.

  • 12-Month Standard Product Warranty

The complete meter is covered by a 12-month warranty from the date of delivery. For non-artificial product failures within the warranty period, we provide free repair service and replacement of defective parts.

  • Lifetime Technical Support & Spare Parts Supply

You receive lifetime remote technical support including commissioning guidance, troubleshooting, calibration advice and parameter configuration. Core spare parts and transmitter replacements are available long-term, avoiding obsolescence risks after years of operation.

 

FAQ

 

Q1: How does a magnetic flow meter work, and what liquids is it suitable for?

A: Operating on Faraday's law of electromagnetic induction, it measures volumetric flow by detecting voltage induced by conductive liquid passing through a magnetic field. It fits conductive liquids (≥5 µS/cm) such as water, wastewater, chemicals, acids, alkalis and slurries, but cannot measure non-conductive media like oil, diesel, deionized water or gas.

Q2: What line sizes and flange standards does this series support?

A: It covers line sizes from ½" to 36" (DN15–DN900) for both small process lines and large municipal pipelines. Compatible flange standards include ASME B16.5 Class 150–2500, DIN PN 10–40, AS 2129 and AWWA C207.

Q3: What is the measurement accuracy and flow range?

A: Standard accuracy is ±0.5% of reading or ±1 mm/s; an optional ±0.2% flat-spec calibration is available for high-precision scenarios. The measuring range spans 4 dm³/min to 9600 m³/h (1 gpm to 44,000 gpm) with excellent turndown ratio.

Q4: How do I choose the right liner material?

A: Select based on medium corrosiveness, abrasiveness and operating temperature:

PTFE / PFA: For corrosive chemicals; high-temperature PFA withstands up to 180°C

ETFE: General industrial use with balanced chemical and abrasion resistance

Polyurethane / Neoprene / Linatex natural rubber: For abrasive slurries and high-solid sewage

Q5: What electrode materials are available for different media?

A: Options include 316L stainless steel, nickel alloy, platinum, tantalum and titanium. 316L fits neutral water and mild chemicals; titanium and nickel alloy suit moderate corrosive media; platinum and tantalum are for strong acids and harsh corrosive conditions.

Q6: What are the maximum medium temperature and process pressure?

A: Maximum medium temperature varies by liner: 180°C (high-temp PFA), 150°C (standard PFA), 130°C (PTFE). Standard process pressure ratings reach PN40, Class 300 and 20K, with higher ratings available on request.

Q7: What output signals and communication protocols are supported?

A: The transmitter offers 4–20mA with HART, Modbus RS485 and programmable relay outputs as standard, with optional WirelessHART for cable-free deployment. It also supports 4–20mA input for external sensor integration.

Q8: What are the key installation requirements?

A: For optimal accuracy, allow at least 5D straight pipe upstream and 2D downstream; 10–15D upstream is recommended after elbows, valves or pumps. With IP67 ingress protection, it is suitable for outdoor and underground manhole installations.

Q9: Can this standard magnetic flow meter be used in partially filled pipes?

A: No. Standard magnetic flow meters require a 100% full pipe to deliver accurate readings; partial fill will cause 30%–100% measurement deviation. For non-full pipe applications, we recommend dedicated area-velocity magnetic flow meters with built-in level sensing.

Q10: How much routine maintenance does it require?

A: With no moving parts, mechanical maintenance is minimal. Annual checks of zero calibration, electrode coating and cable sealing are sufficient. Built-in diagnostics help detect empty pipe conditions and electrode faults without disassembly.

 

For application-specific selection advice, custom liner and electrode configurations, or a formal project quotation, please contact our technical sales team below.

 

Contact now

 

 

 

Hot Tags: Magnetic Flow Meter, China Magnetic Flow Meter manufacturers, suppliers, factory, Electromagnetic Flowmeter, Vortex Flowmeter, flow measurement

Send Inquiry