The Hydrostatic Level Sensor Manufacturer!

 

As a professional manufacturer in the field of industrial automation instruments, Xi'an Xiangyuan Technology Co., Ltd. is dedicated to providing customers with comprehensive liquid level measurement solutions. Our product line covers the following core categories: Magnetic level gauge, radar level sensor, float level gauge, magnetostrictive level gauge, pressure transmitter, flow meter, switches and controllers, Internet of Things smart instrument, etc.

 
  • Hydrostatic Level Sensor
    Measuring range:200mm...4000mmAccuracy:0.2%FS, 0.5%FSProcess connection:Thread≥ G1½, ≥1½ NPT;Flange≥ DN50, ≥2Process pressure:0...25MPaSignal output:4-20mA; Modbus RS-485
 

Why Choose Us

 

 

Our Factory
The production area is more than 1,000 square meters and an office area is about 400 square meters. The main products are magnetic level gauges, level switches, level transmitters etc. Due to the accuracy and reliability of the products, we earn the sustainable trust from our customers for over 10 years.

 

Sales Market
Its products have achieved full coverage in 31 provinces across the country, and it has established long-term cooperation with more than 500 equipment manufacturers and complete set suppliers. The repurchase rate is stable at more than 75%, and some products are exported to Turkey, Russia, Iran and other countries with the equipment.

 

Industry Applications
The company has won high recognition from the market with professional technology and high-quality products and services, and has become a qualified supplier of Changqing Oilfield, Yangtze-Basf, Dalian Aomei, Jinduicheng Molybdenum Industry and other enterprises. At present, a complete customer service system has been established in multiple fields such as petrochemicals, power and energy, and environmental water treatment, and we maintain long-term and stable cooperation with many industry leaders.

 

Measuring medium

Water or liquid compatible with contact materials

Measuring range

200mm...4000mm

Accuracy

0.2%FS, 0.5%FS

Process connection

Thread ≥ G1½, ≥ 1½ NPT

Flange≥ DN50, ≥ 2"

Process temperature

-40...60℃

Process pressure

0...25MPa

Overload pressure

200%FS

Ambient temperature

-40...85℃

Signal output

4-20mA, RS-485

Power supply

24VDC(12-36V)

Process diaphragm material

316L, Aluminum Alloy

Overall material

Isolation diaphragm : 316L

Probe : 304/316L

Seal material : Nitrile rubber

Connect rod : 304/316L

Housing marerial : Cast Aluminum

Maximum Power

Current type: ≤0.02Us(W)

Digital type: ≤0.02Us(W)

IP code

Display Instruments: IP65

Probe: IP68

Electrical connection

Hirschmann connector

 

Advantages of Hydrostatic Level Sensor
 
 

Cost-Effective

Hydrostatic level transmitters offer a cost-effective solution for fluid level measurement, making them accessible to a wide range of industries and applications.

 
 
 

Easy Installation and Maintenance

The installation process is relatively simple, and routine maintenance is minimal, contributing to overall operational efficiency.

 
 
 

Accuracy

Hydrostatic level transmitters provide accurate level measurements, making them suitable for applications where precision is paramount.

 

 

Precautions For The Use Of Static Pressure Liquid Level Transmitter
 

1. Carefully confirm whether the operating conditions of the instrument are appropriate, and note that the power supply voltage is DC 24V.
2. The transmitter and the pressure pipe are exposed to the air, so it is not suitable to use in strong corrosive situations.
3. Dissolved gases and organic solvents lighter than air may damage the transmitter.
4. If strong fluctuations are predicted, only hard pulse tubes can be used, and they should be considered to be installed in a vertical tube.
5. The meter needs to be re-calibrated if the measured liquid ratio changes.
6. The assembled device must be inserted vertically into the liquid.
7. The gas at the junction of the pressure pipe and the gas collector is easy to leak. Pay attention to it when installing.
8. The interface between the pressure pipe and the gas collector pipe and the transmitter should be sealed with 4 fluorine tape or #567 sealant. The glue should be allowed to dry for one hour before immersion to form an airtight whole part.
9. Air/steam can not be discharged from the pressure pipe, and there should be no obvious bubbles at the connection.
10. Because the silicon sensor may be affected by the process, it can only be used for liquids that will not destroy the neoprene rubber and plastic.

静压液位计制造商

 

Types of Hydrostatic Level Transmitters
 

Submersible Level Transmitters

These transmitters are designed to submerge in the liquid fully. They are suspended in the tank and directly measure the pressure at their depth, making them suitable for open tanks and bodies of water. Submersible transmitters often incorporate features like lightning protection for enhanced reliability in demanding environments.

 

Pressure Transmitters

These transmitters are mounted directly onto the side or bottom of the tank. They are typically used in open tanks where direct mounting is feasible.

 

Differential Pressure Transmitters

Differential pressure transmitters are employed to determine the level in closed, pressurized tanks. These transmitters measure the pressure difference between two points. One port is connected to the bottom of the tank, sensing the combined pressure of the liquid and the gas above it. The other port is connected to the top of the tank, sensing only the gas pressure. By subtracting the gas pressure, the transmitter isolates the pressure contribution from the liquid column, enabling accurate level measurement.

 

Applications of Hydrostatic Level Sensor

 

 

1. Water level measurement of water tanks, pools, and rivers
2. Drinking water systems, water treatment plants, and water circulation
3. Liquid level measurement of pump station tanks

 

Packaging & Shipping

 

productcate-938-637

FAQ

 

Q: What is a static pressure gauge?

A: The tool to measure static pressure vs airflow is known as a manometer. To use the manometer, you have to drill into both the supply and return of the HVAC system in question. The static pressure equation is simple: you must add together the measurement from the return and the supply.

Q: What is the difference between static and dynamic pressure gauge?

A: Static pressure is the pressure exerted by a fluid when it is at rest. It is measured perpendicular to the surface of the fluid and is independent of the direction of flow. On the other hand, the dynamic pressure is the pressure exerted by a fluid when it is in motion.

Q: How to calculate static water pressure?

A: The water pressure is calculated by taking the reservoir elevation minus the elevation of the water main in the street then multiplying by 0.433 to determine the pounds per square inch (PSI).

Q: What is the normal static water pressure?

A: In general, residential water pressure ranges between 45-80 psi (pounds per square inch).

We're professional Hydrostatic Level Sensor manufacturers and suppliers in China, specialized in providing high quality customized instruments. We warmly welcome you to buy advanced Hydrostatic Level Sensor made in China here from our factory.

Cable Type Immersion Level Gauge, level measurement, Static Pressure Level Gauge
Send Inquiry