Features
Sensors for non-contact water level measurement, capable of measurement even in harsh environments;
IP68 protection rating;
Maintenance-free as measurement does not require contact with liquid;
High stability even under large and drastic temperature gradients;
Unaffected by condensation and dust;
Antenna size and frequency are two major factors determining the range resolution and accuracy of radar sensors. Smaller antennas result in a larger radar azimuth angle; higher frequencies result in shorter wavelengths.
Stronger signals, less interference: With a smaller azimuth angle, strong signals can be focused more effectively, allowing detection of media with low dielectric constants, as high focusing enhances sensor reflection. High focusing also prevents the detection of devices such as agitators and jet cleaners, thus avoiding signal interference.
High-resolution and accurate level measurement, capable of measuring the entire tank height: For applications such as industrial level sensing, range accuracy (millimeter-level) is crucial. Measurement accuracy and range resolution (i.e., the precision with which changes in level are detected) depend on the transmission frequency. The wide bandwidth of the 77 to 81 GHz band makes range measurements highly accurate. Furthermore, high resolution helps distinguish the level from any interfering reflections from the tank bottom. This allows the sensor to accurately measure the level across the entire height of the tank, minimizing blind spots at the tank bottom. Because high resolution increases the minimum measurable distance, the level at the top of the tank can be measured even when the tank is full.
It maintains high accuracy and reliability even in harsh environments or complex process conditions.
Maintenance costs are low because there are no moving parts and the sensor does not come into contact with materials.
It is resistant to the effects of environmental factors such as high temperature, pressure, and humidity.
How It Works
A radar level sensor is a type of level sensor that uses radar technology to measure the level of liquids or solids in tanks or containers. It works by emitting a radar signal, which is reflected from the material surface and returns to the sensor. The sensor then calculates the level based on the signal's time-of-flight or frequency change. Radar level sensors are non-contact, meaning they do not come into contact with the material being measured, making them ideal for applications requiring extremely high accuracy and reliability. Even under complex conditions such as thin layers of foam or dust, these sensors can accurately measure liquid levels.

The 80 GHz radar level sensor uses Frequency Modulated Continuous Wave (FMCW) technology, where the sensor emits a high-frequency radar signal whose frequency increases in a linear fashion. The radar signal is reflected off the measured medium and returns to the same antenna. The frequency difference between the transmitted and received signals is directly proportional to the distance from the sensor to the material surface.
Using the Fast Fourier Transform (FFT) method, the frequency difference signal is analyzed, and the reflected signal's spectrum is generated. From this spectrum, the level of the material is accurately calculated based on the time it takes for the radar wave to travel to the surface and back.
Applications
Liquid level measurement in storage tanks and containers.
Solid level measurement in silos and hoppers.
Slurry level measurement in mining and wastewater treatment.
Liquid level measurement in food and beverage processing.
Liquid level measurement in chemical and pharmaceutical processing.
Specifications
|
XYRD9091-NCR |
XYRD9092-NCR |
XYRD9093-NCR |
|
|
Applications |
Non-corrosive liquids |
Corrosive liquids with a pH between 7 to 9; corrosive liquids with a pH between 4 to 7 |
Bulk solids, Granule, lump material |
|
Measuring range |
0...10m |
0...120m |
0...120m |
|
Process connection |
G1-1/2 Thread/ Flange≥DN40, 1-1/2"(Optional) |
G3-1/2 Thread/ Flange≥DN100, 3-1/2"(Optional) |
Universal flange, Air purge interface |
|
Process temperature |
-40...120℃ |
-40...120℃ |
-40...120℃ |
|
Process pressure |
-0.1...2MPa |
-0.1...2.0MPa |
-0.1...2.0MPa |
|
Antenna type |
ø22mm lens antenna |
Ø78mm lens antenna |
Ø78mm PTFE lens antenna |
|
Accuracy |
±2mm |
±2mm |
±3mm |
|
Resolution |
±1mm |
±1mm |
±1mm |
|
Frequency |
76...81 GHz |
76...81 GHz |
76...81 GHz |
|
Beam angle |
≈8° |
≈3° |
≈3° |
|
Wetted material |
304/316+PTFE |
304/316+PTFE |
304/316+PTFE |
|
Housing material |
aluminium alloy+Anti-corrosion metal powder coating ,stainless steel |
aluminium alloy+Anti-corrosion metal powder coating ,stainless steel |
aluminium alloy+Anti-corrosion metal powder coating ,stainless steel |
|
Field operation and programming |
128 × 64 dot matrix display/4 keys |
128 × 64 dot matrix display/4 keys |
128 × 64 dot matrix display/4 keys |
|
configurable software for PC setup |
configurable software for PC setup |
configurable software for PC setup |
|
|
IP code |
IP67 |
IP67 |
IP67 |
|
Explosion-Proof |
Ex ia IIC T6 Ga; Ex db IIC T6 Gb |
Ex ia IIC T6 Ga; Ex db IIC T6 Gb |
Ex ia IIC T6 Ga; Ex db IIC T6 Gb |
|
Signal output |
4-20mA+HART OR RS-485 |
4-20mA+HART OR RS-485 |
4...20mA+HART OR RS-485 |
|
Supply |
2-wire /4-wire(DC24V) |
2-wire /4-wire(DC24V) |
2-wire /4-wire(DC24V) |
|
Ambient temperature |
-40...80℃ |
-40...80℃ |
-40...80℃ |
|
Electrical interface |
M20*1.5/ 1/2NPT |
M20*1.5/1/2NPT |
M20*1.5/ 1/2NPT |
|
Features |
The model of product is suitable for the field where the installation space is thread installation; The process connection should be G1-1/2 thread. |
The model of product is used in large-volume liquid working conditions, with the features of small blind area and high precision signal. |
This product has strong signal detection function, small blind measurement area and high accuracy; The beam angle is only 3°, suitable for strong dust conditions. |
|
XYRD9094-NCR |
|
|
Applications |
Corrosive liquid or liquid containing steam |
|
Measuring range |
0...60m |
|
Process connection |
Stainless steel+PTFE flange |
|
Process temperature |
-40...180℃ |
|
Process pressure |
-0.1...2.0MPa |
|
Antenna dimension |
Fully enclosed lens antenna, wetted parts PTFE, flange DN≥ 50,2" |
|
Accuracy |
±2mm |
|
Resolution |
±1mm |
|
Frequency |
76...81 GHz |
|
Beam angle |
≈3° |
|
Wetted material |
PTFE |
|
Housing material |
Aluminium alloy+Anti-corrosion metal powder coating, stainless steel |
|
Field operation and programming |
128 × 64 dot matrix display/4 keys |
|
configurable software for PC setup |
|
|
IP code |
IP67 |
|
Explosion-proof |
Ex iaⅡC T6 Ga; Ex db IIC T6 Gb |
|
Signal output |
4...20mA+HART OR RS-485 |
|
Supply |
2-wire /4-wire(DC24V) |
|
Ambient temperature |
-40...80℃ |
|
Electrical interface |
M20*1.5/ 1/2NPT |
|
Features |
This product has very effective signal, small blind area and high precision; the beam angle is only 3°. |
|
XYRD9095-NCR |
|
|
Applications |
Hygienic, food, beverages,medicine,etc |
|
Measuring range |
0...20m |
|
Process connection |
Hygienic clamp connection |
|
Process temperature |
-40...120℃ |
|
Process pressure |
-0.1...2.0MPa |
|
Antenna dimension |
Ø32mm lens antenna |
|
Accuracy |
±2mm |
|
Resolution |
±1mm |
|
Frequency |
76...81 GHz |
|
Beam angle |
≈ 8° |
|
Wetted material |
PTFE |
|
Housing material |
Aluminium alloy+Anti-corrosion metal powder coating,stainless steel |
|
Field operation and programming |
128 × 64 dot matrix display/4 keys |
|
configurable software for PC setup |
|
|
IP code |
IP67 |
|
Explosion-proof |
Ex iaⅡC T6 Ga; Ex db IIC T6 Gb |
|
Output signal |
4...20mA+HART OR RS-485 |
|
Supply |
2-wire /4-wire(DC24V) |
|
Ambient temperature |
-40...80℃ |
|
Electrical interface |
M20*1.5/1/2NPT |
|
Features |
It is mostly used in pharmaceutical factories and food factories, and the contact surface is all made of PTFE, which is anticorrosive and safe. High precision, small blind area and simple and convenient installation.
|
Hot Tags: 80ghz radar level sensor, China 80ghz radar level sensor manufacturers, suppliers, factory, 26GHz Radar Level Sensor, 80GHz Radar Level Sensor for Basic Applications, 80GHz Radar Level Sensor for Corrosive Liquids, Guided Wave Coaxial Tube Radar Level Sensor, Guided Wave Radar Bypass Tube Level Sensor, Guided Wave Rod Radar Level Sensor