Product Overview
The Cerabar PMP63B is built around a piezoresistive measuring cell and offers two main sensor approaches: a metallic sensor with Contite technology for strong resistance to moisture and condensate, and a diaphragm seal version with TempC membrane for improved stability under temperature fluctuations.
It covers a pressure range from 100 mbar to 100 bar for relative and absolute pressure measurement, with a minimum calibrated span of 5 mbar and a maximum span ratio of 100:1. The device supports multiple communication options, including 4…20 mA HART, PROFIBUS PA, PROFINET with Ethernet-APL, and optional Bluetooth connectivity via the SmartBlue app.
Key Features
- Piezoresistive sensor with diaphragm seal option
Supports direct installation or diaphragm seal mounting for demanding process conditions.
- Contite technology sensor
Provides enhanced resistance to moisture and condensate, especially suitable for cold process environments.
- TempC membrane diaphragm seal
Reduces the influence of temperature fluctuations and improves measurement reliability.
- High accuracy and stability
Standard accuracy up to 0.05 %; Platinum version up to 0.025 %. Long-term stability reaches 0.05 % URL/year.
- Heartbeat Technology
Enables in-situ device verification, process monitoring and advanced self-diagnostics.
- Digital commissioning
Guided setup via local display, web server or SmartBlue app simplifies configuration, proof tests and verification.
- Modern connectivity
Supports 4…20 mA HART, PROFIBUS PA, PROFINET with Ethernet-APL, and optional Bluetooth wireless operation.
- Hygienic and industrial design
Available with hygienic process connections, sanitary certifications and drinking water approvals.
- SIL and international explosion protection
Developed according to IEC 61508 and suitable for SIL2/3 safety applications with multiple Ex certifications.
Technical Specifications
|
Item |
Specification |
|
Measurement principle |
Absolute pressure and gauge pressure |
|
Sensor type |
Piezoresistive sensor with diaphragm seal option |
|
Supply voltage |
4…20 mA HART: 10.5…35 V DC (Non-Ex/Ex d/Ex e); 10.5…30 V DC (Ex ia); PROFINET with Ethernet-APL: 9.6…15 V DC; PROFIBUS PA: 9…32 V DC (Non-Ex/Ex d/Ex e), 9…24 V DC (Ex i) |
|
Reference accuracy |
Standard: up to 0.05 %; Platinum: up to 0.025 % |
|
Long-term stability |
0.05 % URL/year; 0.07 % URL/5 years; 0.10 % URL/10 years |
|
Process temperature |
Standard: -40…125 °C; Diaphragm seal: -40…250 °C |
|
Ambient temperature |
-40…85 °C |
|
Sensor range |
100 mbar…100 bar (1.5 psi…1500 psi), relative/absolute |
|
Minimum calibrated span |
5 mbar (0.075 psi) |
|
Vacuum resistance |
5 mbar (0.075 psi) |
|
Span ratio |
Up to 100:1 |
|
Maximum overpressure limit |
Up to 400 bar (6000 psi) |
|
Process connections |
Thread: G1/2…G2, MNPT1/2…MNPT2; Flange: DN25…DN80, NPS 1"…3"; Diaphragm seal |
|
Hygienic connections |
Tri-Clamp, DIN11851, DIN11864, NEUMO, Varivent, SMS, DRD, Anderson, Sanitary tank spud, Universal adapter |
|
Wetted materials |
316L, Alloy C |
|
Seal / diaphragm |
Diaphragm welded, no separate gasket |
|
Fill fluid |
Silicone oil, synthetic oil, vegetable oil, high-temperature oil |
|
Housing |
Aluminum, 316L hygienic |
|
Communication |
4…20 mA, 4…20 mA HART, PROFIBUS PA, PROFINET with Ethernet-APL, Bluetooth (optional) |
|
Certifications |
ATEX, CAN/US, IEC Ex, JPN Ex, KC Ex, INMETRO, NEPSI, UK Ex |
|
Safety / design / hygienic |
SIL; EN 10204-3.1; ASME-BPE, cGMP, 3A, EHEDG; KTW, NSF drinking water approval |
Typical Applications
- Hydrostatic level measurement in open and pressurized tanks
- Absolute and gauge pressure monitoring in liquids and gases
- Cold process and storage tank level measurement
- Process piping pressure monitoring during product transfer
- Head pressure and level measurement in fermentation and cell culture tanks
- Clean steam pressure monitoring during SIP processes
- Food, beverage and pharmaceutical hygienic processes
- Applications requiring Ethernet-APL, HART or PROFIBUS PA integration
Frequently Asked Questions
What is the difference between the Contite sensor and the diaphragm seal version?
The Contite sensor provides strong moisture and condensate resistance, making it suitable for cold process environments. The diaphragm seal version with TempC membrane is better suited for applications with significant temperature fluctuations.
Does the PMP63B support Ethernet-APL?
Yes. It supports PROFINET with Ethernet-APL, enabling high-speed two-wire communication and simplified integration into modern digital automation systems.
Can the PMP63B be used in hygienic applications?
Yes. It is available with hygienic process connections and holds certifications such as 3A, EHEDG, ASME-BPE and cGMP. Drinking water approvals including KTW and NSF are also available.
Is the PMP63B suitable for safety-related applications?
Yes. It is developed according to IEC 61508 and can be used in SIL2/3 safety applications.
Can the device be operated wirelessly?
An optional Bluetooth module is available. With the SmartBlue app, users can commission, operate and maintain the device wirelessly.
If you need a quotation for the Endress+Hauser Cerabar PMP63B, please provide the complete manufacturer type code. We can provide pricing based on the specified selection code.We will review the code and return a quotation accordingly.
Hot Tags: cerabar pmp63b digital pressure transmitter, China cerabar pmp63b digital pressure transmitter manufacturers, suppliers, factory