Cerabar PMP71B Pressure Transmitter

Cerabar PMP71B Pressure Transmitter
Details:
The Cerabar PMP71B is Endress+Hauser's metal-diaphragm pressure transmitter for absolute and gauge pressure measurement across a 400 mbar to 700 bar range. It pairs a welded metallic process diaphragm with 4-20mA HART or PROFINET/Ethernet-APL communication, optional Bluetooth operation through the SmartBlue app, and built-in Heartbeat Technology that lets you verify device health without shutting the process down. Available with diaphragm seals extending process temperatures to 400°C, SIL certification, and global hazardous-area approvals including ATEX, IECEx, CSA, INMETRO and NEPSI.
Send Inquiry

Product Overview

 

The Cerabar PMP71B belongs to Endress+Hauser's Cerabar family of piezoresistive pressure transmitters, designed for continuous pressure and level measurement in process industries. Unlike simpler transmitters that only output a pressure value, the PMP71B bundles configuration, verification and diagnostic functions into a single device - the stated goal being that an operator can check whether the instrument is still performing within specification without isolating it from the line.

At its core is a welded metallic process diaphragm. The measuring cell covers 400 mbar to 700 bar, with a smallest calibratable span of 5 mbar and a maximum turn-down of 100:1. Reference accuracy runs up to 0.05% under the standard cell and up to 0.025% in the Platinum version. Long-term stability is specified at 0.05% of URL per year, which is the number that matters most in custody transfer and safety loops rather than the initial calibration accuracy.

The PMP71B is a flexible platform rather than a single SKU. You can order it with threaded or flanged process connections, six different process diaphragm materials (316L, Alloy C, tantalum, Monel, PTFE and gold), and four fill-fluid options (silicone oil, inert oil, vegetable oil, high- or low-temperature oil). It supports traditional wired 4-20mA HART, newer PROFINET with Ethernet-APL for industrial Ethernet, and optional Bluetooth for wireless commissioning and maintenance through E+H's SmartBlue app.

 

What Sets the PMP71B Apart

 

Heartbeat Technology - verify without interrupting the process

Heartbeat Technology is E+H's term for on-board self-verification. The idea is that during normal operation the transmitter runs a structured check of the sensor, electronics and signal path, and produces a verifiable result. In practice this matters in three situations:

SIL proof-test scheduling. Safety instrumented systems require periodic proof tests. With Heartbeat, a partial or full verification can be initiated from the control room or via the SmartBlue app without breaking the process loop, reducing the number of times you have to isolate the transmitter.

Regulated industries. In pharma, food and beverage, and custody transfer applications, you need documented evidence that the instrument is still in tolerance. The verification report can be logged for audit.

Predictive maintenance. Instead of waiting for a drift alarm, you trend the verification results over time and replace the cell on a schedule that matches actual wear.

E+H also includes guided wizards for commissioning, proof tests and verification, so a technician walks through a step-by-step on the local display or app rather than working from a manual.

HistoROM data storage and plug-and-play

The PMP71B carries a HistoROM module - E+H's term for the EEPROM that stores sensor parameters, configuration data and device history. If the electronics housing needs to be replaced in the field, the HistoROM can be moved to the new module and the transmitter powers up with its previous configuration intact. No re-commissioning from scratch, no risk of losing a calibrated tag.

Bluetooth operation with the SmartBlue app

An optional Bluetooth module connects the transmitter to E+H's SmartBlue app on a phone or tablet. This is most useful in two cases: transmitters mounted high on a tank or inside a guard-rail where climbing or reaching with a HART communicator is awkward, and transmitters in hazardous areas where a wireless connection removes the need to open the housing while energized. Connection range is typically on the order of a few meters in open air, which is enough for ground-level commissioning from the base of a vessel.

LED status module and RFID tag

A top-side LED module gives a quick visual status (normal, warning, fault) from a distance, which speeds up field walk-downs. An RFID tag on the housing lets maintenance staff scan the device with a phone to pull up its tag number, configuration and documentation without a handheld interrogator.

 

Technical Specifications

 

All figures below are taken from E+H's published PMP71B datasheet. Exact ordering depends on cell size, diaphragm material and approval combination - confirm with the nameplate or a current datasheet for your specific variant.

 

Item

Specification

Measuring principle

Absolute pressure and gauge pressure

Characteristic

Pressure transmitter with metallic process diaphragm; diaphragm seal options available

Measuring cell range

400 mbar … 700 bar (6 psi … 10,500 psi)

Smallest calibratable span

5 mbar (0.075 psi)

Maximum turn-down

100:1

Reference accuracy - standard

Up to 0.05%

Reference accuracy - Platinum

Up to 0.025%

Long-term stability

0.05% URL/year; 0.07% URL/5 years; 0.10% URL/10 years

Overpressure limit (max.)

1,050 bar (15,750 psi)

Vacuum resistance - standard cell

10 mbar (0.145 psi)

Vacuum resistance - diaphragm seal

50 mbar (0.725 psi)

Process temperature - standard

-40°C … +125°C (-40°F … +257°F)

Process temperature - diaphragm seal

-70°C … +400°C (-94°F … +752°F)

Ambient temperature

-60°C … +80°C (-76°F … +185°F)

Output signal

4-20mA HART; PROFINET with Ethernet-APL

Wireless option

Bluetooth with SmartBlue app

Supply voltage (Ex d / Ex e / non-Ex)

10.5 … 35 V DC

Supply voltage (Ex i intrinsic safety)

10.5 … 30 V DC

Process connection - thread

G1/2 … G2, R1/2, MNPT3/4 … MNPT2, FNPT1/2, R1/2

Process connection - flange

DN25 … DN100, NPS 1" … 4"

Process connection - pancake

2" … 4", DN50 … DN100

Process diaphragm materials

316L, Alloy C, tantalum, Monel, PTFE, gold

Gasket material

PTFE

Fill fluids

Silicone oil, inert oil, vegetable oil, high-temperature / low-temperature oil

Housing materials

Aluminum, 316L stainless steel

Hazardous-area approvals

ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex

Safety approvals

SIL

Design / material approvals

EN 10204 3.1, NACE MR0103, NACE MR0175

Marine approvals

Yes (per listed marine certifications)

Drinking water approval

NSF

Special functions

Heartbeat Technology, Bluetooth SmartBlue app, LED status module, RFID identification tag, HistoROM data storage, plug-and-play replacement

 

Typical Applications

 

The PMP71B is a general-purpose process transmitter that can be ordered into demanding service rather than a single-use instrument. Common deployments include:

Oil & gas and upstream processing. NACE MR0175/MR0103 compliance makes it suitable for sour service; the range up to 700 bar covers wellhead and high-pressure separator duties. Diaphragm seals with high-temperature fill fluid handle hot process streams.

Chemical and petrochemical. Alloy C, tantalum and Monel diaphragm options target corrosive and chloride-containing media where a standard 316L diaphragm would fail. PTFE and gold-plated diaphragms cover aggressive or sticky services.

Power and boiler service. With diaphragm seals rated to 400°C and high-temperature fill fluid, the PMP71B is used for steam pressure, feedwater and turbine auxiliary systems. The -60°C low-end ambient rating suits outdoor and cold-climate installations.

Food, beverage and pharma. NSF drinking-water approval and the option of vegetable-oil fill fluid (which is FDA-compliant for food contact and safe in the event of diaphragm rupture) make it acceptable for potable water, dairy and clean-in-place processes. EN 10204 3.1 material certificates support pharma documentation.

Pulp, paper and mining. Flanged and pancake process connections, plus a range of corrosive-slurry diaphragms, fit digesters, bleach plants and mineral processing circuits.

Tank level measurement. When matched with a diaphragm seal and capillary, the PMP71B is used as a hydrostatic level transmitter on storage tanks and vessels, including in hazardous-area farms.

 

Frequently Asked Questions

 

Q1: What is the difference between the standard and Platinum accuracy versions?

A: The standard cell reaches up to 0.05% reference accuracy; the Platinum version is trimmed to up to 0.025%. Platinum is typically chosen for custody transfer, differential flow metering that depends on a stable pressure reference, and safety loops where tighter uncertainty directly reduces trip-point margin. For most routine pump and vessel pressure indication, the standard cell is sufficient.

Q2: Can the PMP71B be used as a drop-in replacement for an older Cerabar unit?

A: The PMP71B is the current-generation Cerabar transmitter. Process connection dimensions and HART command set are broadly compatible with earlier Cerabar models, but the housing, display and HistoROM module are not mechanically interchangeable with every older variant. If you are replacing a specific older model, share the old tag number and flange spec and we can cross-check dimensions and wiring before ordering.

Q3: What does Heartbeat verification actually produce?

A: It runs a sensor and electronics self-check and outputs a "passed" or "failed" result, together with a tamper-evident verification record that can be exported. It is not a substitute for a calibration against a traceable reference - it is an in-situ check that flags drift or sensor degradation between external calibrations.

Q4: Does Bluetooth work in hazardous areas?

A: The Bluetooth module is approved for use in the same hazardous-area zones as the transmitter itself, under the corresponding ATEX/IECEx/CSA certificate. It does not require opening the housing or energizing any internal terminals. Always verify the specific certificate number on the device label against your site's hazardous-area classification.

Q5: How does the 100:1 turn-down affect accuracy?

A: The 100:1 figure is the ratio between the upper range limit and the minimum span you can calibrate. Accuracy specifications are quoted at reference conditions and at a stated turn-down - if you crank the turndown to the maximum, the achievable accuracy will be somewhat wider than the headline 0.05% number. For safety-critical loops, size the cell so your normal operating pressure sits between 30% and 90% of cell span rather than turning a 700 bar cell down to measure 7 bar.

Q6: Can it be ordered with both 4-20mA HART and PROFINET on the same unit?

A: No - communication interface is ordered as a hardware variant. You choose either the 4-20mA HART electronics or the PROFINET/Ethernet-APL version when placing the order. Bluetooth is an add-on option available across both variants.

Q7: What fill fluid should I choose for oxygen service?

A: Standard silicone oil is not suitable for high-pressure oxygen service. Inert fill fluids are used for oxygen and other strongly oxidizing media - confirm the specific fill fluid and its compatibility with oxygen and your process temperature with E+H or with us before ordering, because oxygen-compatible fluids are a separate approval chain.

Q8: Is the PMP71B suitable for vacuum service?

A: The standard cell resists down to 10 mbar absolute; the diaphragm-seal version to 50 mbar absolute. For deep vacuum below those limits, or for full vacuum with pressure cycling, specify a vacuum-rated diaphragm seal and capillary arrangement rather than a standard threaded connection.

Q9: What is HistoROM and why does it matter in the field?

A: HistoROM is the pluggable memory module that holds the sensor trim data, device configuration and operation log. If the electronics fails on a cold tank or in a remote station, you can swap the electronics housing, move the HistoROM across, and the transmitter comes back online with the same configuration - no laptop, no HART modem, no re-zeroing. It is one of the more practical field-service features on the PMP71B platform.

 

We provide quotations for the Endress+Hauser Cerabar PMP71B pressure transmitter based on your complete part number or clear information from the product nameplate.

Please share the below information for us to check availability and prepare your formal quote:

  • Full PMP71B  model number
  • Nameplate photo of the transmitter (preferred)
  • Required quantity
  • Target delivery destination

Kindly provide the full model number or transmitter nameplate photo for quotation. We cannot prepare an ordering code from P&ID tags or general process specifications alone.

Our team will review your submission promptly and get back to you with pricing and lead time details.

 

 

 

 

Contact now

 

 

 

 

 

 

Hot Tags: cerabar pmp71b pressure transmitter, China cerabar pmp71b pressure transmitter manufacturers, suppliers, factory, Coplanar Pressure Transmitter, In line Pressure Transmitter, pressure measurement, submersible hydrostatic level transmitter, Submersible Pressure Transmitter, submersible water level transmitter

Send Inquiry