The Steam/Hot Water/Vacuum Jacket Type Magnetic Level Gauge is a specialized bypass level indicator engineered for liquid level and interface monitoring of temperature-sensitive media, such as easily crystallized, high-viscosity, easily solidified or cryogenic liquids. Based on the communicating vessel principle with magnetic float coupling technology, it integrates an external jacket structure for steam tracing, hot water heating or vacuum insulation, fundamentally eliminating measurement failures caused by medium solidification, pipe wall crystallization or low-temperature frosting.
Available in a single-section design up to 5500 mm and multi-section spliced structures for longer measuring ranges, this jacketed level gauge supports a wide working pressure range from 16 bar to 250 bar and an operating temperature span of -40°C to +400°C. The main process chamber is available in 304 or 316L stainless steel (custom alloys on request), paired with 316L or titanium floats to match different medium corrosion and density properties.
It is supplied with complete process connection options, including flanges from DN15 to DN50 (PN16 to PN320 / Class 150 to Class 1500), as well as welding or threaded studs. Standard vent and drain connections are provided for routine commissioning, while the jacket circuit adopts dedicated flange or threaded ports for steam/hot water circulation or vacuum pumping, with a maximum jacket working pressure of 10 bar.
Widely used in petrochemical, chemical, pharmaceutical, food processing and cryogenic storage systems, this gauge delivers clear local visual level indication without external power supply, maintaining reliable readings even during plant power outages. It can also be equipped with level alarm switches and remote transmitters upon request, serving as a safe, maintenance-free level measurement solution for temperature-controlled process media.
Technical Data
Below is the full technical specification table for this steam, hot water and vacuum jacketed magnetic level gauge. It details measuring ranges, jacket dimensions, pressure and temperature ratings, process and jacket connection options, wetted material selections, sealing configurations and float specifications. You can use these data to verify compatibility with your on-site tracing, heat preservation or cryogenic insulation requirements. For custom material grades, multi-section extended ranges or special interface needs, our technical team is ready to provide tailored solutions.
|
PN16...PN250 CLASS150...CLASS1500 |
|
|
Principle |
Communicating tubes with magnetic float |
|
Measurement |
Level or interface |
|
Mounting position |
Vertical |
|
Measuring range |
Max. 5500 mm (one part), > 5500 mm 2- or multipart |
|
Pipe size |
Φ 57 mm\ Φ 60.3 mm Welding stud or necking welding |
|
Pipe material |
304, 316L (Other materials also available) |
|
Process connection |
Flange: DN15...50 PN16...320 (½ -1 ½" 150# -1500#) Welding or threaded stud |
|
Vent connections |
Without or Plug R½" |
|
Drain connections |
Plug R½" or valve (Other request also available) |
|
Jacket pipe size |
Φ 76×2 mm, Φ 89×2 mm |
|
Jacket pressure |
Max.10bar |
|
Process connections for jacket (not for vacuum jacket) |
Flange: DN15\DN20 PN16(150#) Threaded stud NPT1/2, G1/2" |
|
Flange material |
Same as pipe material |
|
Float material |
316L or Ti |
|
Operation temperature |
-40...+ 400°C |
|
Operation pressure |
Max.16 bar~250bar |
|
Density |
Min. 0.4kg/dm³, For interface: Density difference≥0.2kg/dm³ |
|
Bolts/Nuts |
CS, SS |
|
Gaskets |
PTFE up to 200°C, Metal graphite up to 400°C |
|
Indication rail |
Aluminium up to 400°C |
|
Magnetic flap or column |
PA up to 120°C Aluminium up to 400°C |
|
Measuring scale |
Aluminium, SS |
|
Float types |
Cylindrical, sealed type |
|
Float length |
Depend on density |
Features
- Three Jacket Configurations for Temperature-Sensitive Media
Steam jacket, hot water jacket and vacuum jacket are available to match different working requirements. Steam and hot water jackets provide continuous tracing (max jacket pressure 10 bar) to prevent crystallization, solidification and viscosity increase of high-melting-point media; vacuum jacket offers thermal insulation for cryogenic liquids to avoid wall condensation and frosting, ensuring uninterrupted level measurement.
- Flexible Single & Multi-section Range Design
Single-section measuring length reaches up to 5500 mm; for tanks deeper than 5500 mm, 2-section or multi-section spliced structures are available. The vertical bypass chamber adopts Φ57 mm or Φ60.3 mm pipe diameter with welding stud or necking welding process, ensuring structural strength and smooth float movement.
- Wide Pressure & Temperature Adaptation for Harsh Processes
Rated working pressure ranges from 16 bar to 250 bar, and operating temperature covers -40°C to +400°C, adapting to high-temperature heat transfer oil, medium-pressure process vessels and low-temperature cryogenic storage conditions. Display components are graded by temperature: PA magnetic flaps for up to 120°C, aluminum indication rail and columns for up to 400°C.
- Reliable Level & Interface Dual Measurement
Operating on the communicating vessel + magnetic float coupling principle, it supports both single liquid level and liquid-liquid interface measurement. It requires minimum medium density of 0.4 kg/dm³ for level detection, and minimum density difference of 0.2 kg/dm³ for interface measurement. Cylindrical sealed floats in 316L or titanium are customized according to actual medium density.
- Complete Connection Options & Customizable Configurations
Process connections cover full-specification flanges (DN15–DN50, PN16–PN320 / Class 150–Class 1500) and welding/threaded studs. Standard R½" plug vent and drain connections can be upgraded with valves on request. Jacket ports are available in DN15/DN20 PN16 flanges or NPT1/2 / G1/2" threaded studs for easy integration with on-site tracing systems.
- Graded Material Matching for Sealing Reliability
Main pipe is available in 304, 316L stainless steel or custom alloys, with flange material consistent with the pipe body. Gaskets are selected by temperature grade: PTFE for temperatures up to 200°C, and metal graphite for temperatures up to 400°C. Carbon steel or stainless steel bolts and nuts are provided accordingly to ensure long-term sealing under high pressure and temperature cycles.
- Power-free Visual Indication & Lifelong Maintenance-free
The magnetic flap/column display delivers clear continuous local readings driven purely by mechanical magnetic coupling, requiring no external power supply and remaining fully functional during power outages. With no internal wearing parts and fully isolated display from process media, it operates stably for long periods with only routine appearance inspection, greatly reducing on-site maintenance costs.
Product Applications
This steam/hot water/vacuum jacketed magnetic level gauge operates on the communicating vessel principle with magnetic float coupling, delivering power-free local visual level indication. Its integrated external jacket structure provides active heating or passive thermal insulation, specifically engineered for temperature-sensitive process media that easily crystallize, solidify, thicken or frost at ambient temperatures. It fills the measurement gap where standard bypass level gauges fail due to medium state changes, and is widely deployed in the following targeted industrial scenarios:
1. Petrochemical High-Viscosity & Easily Crystallized Medium Storage Tanks
Ideal for storage tanks and bypass pipelines carrying heavy oil, asphalt, paraffin, molten sulfur and other high-melting-point media. The steam jacket provides continuous tracing at up to 10 bar jacket pressure, preventing medium crystallization and solidification inside the bypass chamber to avoid float jamming and measurement failure. It supports both single liquid level and oil-water interface measurement, with a minimum medium density of 0.4 kg/dm³ and a required density difference ≥ 0.2 kg/dm³ for interface detection. Rated for working pressures up to 250 bar and temperatures up to 400°C, with 316L or titanium float options for corrosive heavy process media.
2. Cryogenic Storage & Low-Temperature Chemical Process Systems
Specially suited for cryogenic liquid storage tanks and low-temperature solvent process lines such as liquid ammonia, cryogenic reagents and liquefied industrial gases. The vacuum jacket forms an isolated thermal insulation layer between the process chamber and the external environment, preventing wall frosting, condensate accumulation and medium vaporization caused by ambient temperature differences. It operates reliably at temperatures as low as -40°C, with aluminum indication rails and flaps adapted to wide temperature cycles. Its fully mechanical power-free design eliminates electrical ignition risks, making it suitable for hazardous area cryogenic storage zones.
3. Pharmaceutical & Food Hot-Melt Material Process Vessels
Applied to preparation tanks and storage vessels for hot-melt adhesives, pharmaceutical greases, food-grade syrups and chocolate slurries. The hot water jacket delivers mild and uniform circulating heating, avoiding local overheating and material deterioration caused by direct high-temperature tracing. Wetted parts in 304/316L stainless steel match sanitary process requirements, and PTFE gaskets are standard for working temperatures up to 200°C. Clear distant-visible magnetic flap indication allows operators to read levels safely without approaching high-temperature vessels.
4. Heavy Oil Settling & Oil-Water Separation Tanks
Deployed in oilfield and petrochemical heavy oil settling tanks and three-phase separators. Steam tracing maintains fluidity of heavy crude oil and viscous oily media inside the bypass chamber, ensuring the float moves smoothly with level fluctuations. It simultaneously monitors total liquid level and oil-water interface to support separation process control, with multi-section spliced structures available for large settling tanks exceeding 5500 mm in height. Full-range flange connections (Class 150 to Class 1500) fit high-pressure separation vessels directly.
5. Outdoor Cold-Region Storage Tanks & Skid-Mounted Units
Designed for outdoor process tanks and skid-mounted equipment in cold regions where winter temperatures drop sharply. Steam or hot water jacket tracing prevents medium freezing and congelation inside the bypass pipeline, guaranteeing uninterrupted level monitoring even at -40°C ambient temperature. Vertical bypass installation with flange, welding stud or threaded stud connections adapts to compact skid structures. Its wear-free magnetic coupling structure requires no routine maintenance, reducing on-site inspection workload for unattended outdoor stations.
6. Fine Chemical High-Melting-Point Reactor Bypass Systems
Used for bypass level monitoring of high-melting-point material reactors in fine chemical production. The jacket tracing system synchronizes with the reactor temperature control system, ensuring consistent medium state between the bypass chamber and the reactor body and eliminating measurement deviation caused by temperature difference. Process flanges from DN15 to DN50 with pressure ratings from PN16 to PN320 match various reactor nozzle specifications. Optional level alarm switches and remote transmitters can be mounted externally via magnetic coupling for interlock protection and DCS data upload without tank modification.
Product Guarantees
Our steam, hot water and vacuum jacketed bypass magnetic level gauges hold official ECM certification. This certificate verifies that the product complies with EU industrial equipment safety and performance standards, and maintains compliant and reliable performance under rated high-pressure and wide-temperature working conditions. It is fully applicable to international engineering projects, export procurement and industrial sites with strict regulatory requirements.

FAQ
Q1: What is a jacketed magnetic level gauge, and how does it differ from a standard bypass model?
A1: It is a specialized bypass level indicator with an external jacket structure added to the main measuring chamber. Unlike standard magnetic level gauges, it supports steam tracing, hot water heating or vacuum insulation to maintain proper medium state inside the chamber. It solves measurement failures caused by medium crystallization, solidification or frosting that standard models cannot handle, while retaining the communicating vessel principle and power-free local visual indication.
Q2: What types of jackets are available, and how to make a selection?
A2: Three jacket configurations are provided for different working requirements:
- Steam jacket: High-efficiency continuous tracing, ideal for high-melting-point, easily crystallized and high-viscosity media such as asphalt and paraffin.
- Hot water jacket: Mild and uniform heating, suitable for heat-sensitive materials that cannot bear local overheating, such as pharmaceutical and food-grade slurries.
- Vacuum jacket: Passive thermal insulation for cryogenic media, preventing wall frosting and condensation, suitable for low-temperature liquid storage systems. Maximum jacket working pressure is 10 bar for steam and hot water types.
Q3: What is the maximum measuring range? Can it be used for extra-deep tanks?
A3: A single-section unit supports a maximum measuring length of 5500 mm. For tanks deeper than 5500 mm, 2-section or multi-section spliced structures are available to meet extended range requirements. The vertical bypass chamber adopts Φ57 mm or Φ60.3 mm pipe diameter with welding stud or necking welding process, ensuring smooth float movement across spliced sections.
Q4: Can it measure liquid-liquid interface? What are the density requirements?
A4: Yes, it supports both single liquid level and liquid-liquid interface measurement. For single level detection, the minimum medium density is 0.4 kg/dm³. For interface measurement, the density difference between upper and lower liquid layers must be ≥ 0.2 kg/dm³. Cylindrical sealed floats in 316L or titanium are customized according to actual medium density to ensure accurate buoyancy drive.
Q5: What process connection options are provided?
A5: Multiple connection solutions match different tank nozzle specifications:
- Flange connections: DN15 to DN50, pressure ratings from PN16 to PN320 (Class 150 to Class 1500)
- Welding studs and threaded studs Standard vent and drain ports come with R½" plugs, and drain valves or custom vent/drain configurations are available on request.
Q6: What connection interfaces does the jacket circuit have?
A6: For steam and hot water jackets, dedicated circulation interfaces are provided:
- Flange type: DN15 / DN20, PN16 (Class 150)
- Threaded stud type: NPT1/2, G1/2" The vacuum jacket is equipped with dedicated pumping ports. All jacket ports are designed for seamless integration with on-site tracing pipelines or vacuum systems.
Q7: What wetted material options are available for corrosive and high-temperature media?
A7: The main measuring chamber is available in 304 or 316L stainless steel, with custom alloy materials available on request. Float options include 316L stainless steel and titanium.Gaskets are graded by operating temperature: PTFE gaskets for temperatures up to 200°C, and metal graphite gaskets for temperatures up to 400°C. Indication components are also temperature-rated: PA magnetic flaps for up to 120°C, aluminum rails and columns for up to 400°C.
Q8: What are the working pressure and temperature limits?
A8: Rated working pressure ranges from 16 bar to 250 bar, and operating temperature covers -40°C to +400°C, adapting to working conditions from cryogenic storage to high-temperature hot medium vessels. The jacket structure does not reduce the pressure rating of the main process chamber.
Q9: What types of media is this level gauge most suitable for? A9: It is specifically designed for temperature-sensitive media that standard bypass level gauges cannot reliably measure:
- High-melting-point and easily crystallized media: asphalt, paraffin, molten sulfur, brine
- High-viscosity media: heavy oil, grease, food-grade syrup
- Cryogenic and easily frosted media: liquid ammonia, cryogenic reagents, liquefied industrial gases
- Constant-temperature process media: pharmaceutical hot-melt materials, fine chemical reaction solutions
Q10: Does the level indication require external power supply?
A10: No. The level display is driven purely by mechanical magnetic coupling between the internal float and external magnetic flaps, requiring no external power supply. The local reading remains fully functional even during total plant power outages, ensuring continuous level monitoring for safety-critical processes. The jacket heating/insulation system relies on external steam, hot water or vacuum supply, independent of the level indication function.
Q11: Can alarm switches and remote transmitters be added later?
A11: Yes. Level alarm switches and remote level transmitters can be externally mounted on the indication rail via magnetic coupling, without modifying the main chamber or jacket structure. This realizes on-site level interlock protection and remote DCS data upload while retaining the power-free local visual display.
Q12: Does this product have international compliance certification?
A12: Yes. Our magnetic level gauges hold official ECM certification. The product complies with EU industrial equipment safety and performance standards, and is suitable for international engineering projects and export procurement.
If you require this steam/hot water/vacuum jacketed magnetic level gauge for easily crystallized, high-viscosity or cryogenic media, please submit your inquiry with detailed working parameters, jacket type requirements and tank connection specifications. Our technical team will recommend the optimal configuration tailored to your actual process conditions.
Hot Tags: Magnetic Level Gauge Steam/Hot Water/Vacuum Jacket Type, China Magnetic Level Gauge Steam/Hot Water/Vacuum Jacket Type manufacturers, suppliers, factory, Side Mounted Lining PTFE Magnetic Level Gauge, Side Mounted PP Magnetic Level Gauge, Top Mounted PP Magnetic Level Gauge, Side Mounted PVDF Magnetic Level Gauge, Hot water jacketed Magnetic level gauge, Top Mounted Magnetic Level Gauge