Deltabar FMD72 Electronic Differential Pressure Transmitter

Deltabar FMD72 Electronic Differential Pressure Transmitter
Details:
The Endress+Hauser Deltabar FMD72 is an electronic differential pressure level system designed for pressurized tanks and distillation columns. It eliminates impulse lines and capillaries by using two separate HP and LP digital sensor modules mounted directly on the vessel. The transmitter calculates differential pressure, level, volume and mass digitally, removing temperature drift, plugging and heat-tracing maintenance common to conventional DP installations. It supports 4-20mA HART multivariable output, hygienic wetted options and hazardous-area approvals.
Send Inquiry

Product Overview

 

On a pressurized tank or a tall distillation column, getting a trustworthy level reading usually means running impulse piping between the vessel and the transmitter - and then living with all the recurring issues that piping brings.

The Deltabar FMD72 from Endress+Hauser removes that entire section of the installation. Two metal sensor modules sit directly at the high-pressure and low-pressure measuring points on the vessel and communicate digitally with a central transmitter. Liquid level, volume or mass is calculated within the transmitter electronics, instead of transferring pressure through a fluid-filled impulse line or capillary.

 

Three Components, One Measurement

 
  • HP sensor module Mounted on the lower vessel nozzle, it measures hydrostatic pressure generated by the liquid column.
  • LP sensor module Installed above the maximum liquid level, it captures the vapor space head pressure inside the tank.
  • Transmitter unit It receives digital pressure values from both sensors, computes the differential pressure, and converts the result into level, volume or mass. Since signals are transmitted digitally, the transmitter can be mounted remotely on a pipe or wall bracket for convenient access. Individual process pressures and sensor temperatures are continuously available for monitoring.

 

On-site Advantages Compared with Classic DP Installations

 

Traditional impulse-line DP setup Deltabar FMD72 electronic DP system
Readings drift with daily and seasonal ambient temperature changes No fluid-filled impulse column, no temperature-induced measurement shift
Impulse lines suffer from condensation, evaporation and blockages No impulse lines; these failure modes are completely eliminated
Winter operation requires heat tracing and insulation Heat tracing and insulation are not needed, cutting installation and operating costs
Pipework and fittings create multiple potential leak points Fully electronic signal path, far fewer sealed joints
Only a single differential pressure value is sent to the control room HART delivers differential pressure, top vapor pressure and individual sensor temperatures from one system
Full health assessment of the measurement loop is difficult Built-in HART diagnostics monitor the complete measuring chain
Commissioning requires experienced technicians and lengthy setup Menu-guided wizards walk installers through configuration step by step

 

Measuring Performance

 

Parameter Detail
Measuring principle Differential pressure, calculated from two independent digital sensor signals
Reference accuracy 0.075 % per sensor; 0.05 % per sensor with Platinum option
Long-term stability 0.05 % of URL per year, per sensor
Sensor span 400 mbar … 10 bar (6 … 150 psi)
Vacuum resistance 10 mbar abs.
Overload limit 160 bar (2400 psi)
Output and power 4…20 mA with HART; 12…45 V DC for non-Ex, 12…30 V DC for Ex ia

 

Process Conditions and Wetted Parts

 

Parameter Detail
Medium temperature –40 … +125 °C (–40 … +257 °F)
Ambient temperature –40 … +80 °C (–40 … +176 °F)
Wetted materials 316L; Alloy C
Filling liquid Silicone oil or synthetic oil
Standard connections Threads and flanges to DIN, ASME or JIS
Hygienic connections DIN 11851, DIN 11864-1, Tri-Clamp, DRD, Varivent
Housing material Powder-coated die-cast aluminum or stainless steel

 

Approvals and Options

 

Category Coverage
Explosion protection ATEX, FM, CSA (incl. CSA C/US), IECEx, NEPSI, INMETRO
Design certificates NACE MR0175, EN 10204-3.1
Hygienic listings EHEDG, 3A, FDA
Factory options Four-line digital display; aluminum or stainless-steel housing

 

Typical Applications

 

  • Liquid level, volume and inventory monitoring for pressurized storage and process vessels
  • Distillation columns and evaporators in chemical and petrochemical plants
  • Retrofit projects where existing impulse piping causes repeated maintenance trouble
  • Outdoor storage tanks exposed to large seasonal temperature swings
  • Food, beverage and pharmaceutical production requiring hygienic process connections
  • Facilities feeding multivariable process data and diagnostic status into asset management platforms

 

Sizing and Ordering

 

Endress+Hauser provides the Applicator sizing tool for electronic differential pressure. This tool calculates the correct sensor ranges and system configuration for your vessel geometry and operating conditions before order placement.

Once the final configuration is confirmed, send us the complete manufacturer type code. Our team will verify the selection and prepare your quotation.

 

Frequently Asked Questions

 

Q: Which parts make up one complete FMD72 system?

A: One system consists of two metal sensor modules (HP and LP) plus one transmitter, together with mounting hardware. HP and LP modules are specified separately to match vessel nozzle positions, and all three units are commissioned as one integrated measuring system.

Q: Besides level, what other process data can be accessed?

A: The HART signal carries vessel top pressure, individual sensor temperatures, calculated differential pressure and full system diagnostic data alongside the primary level reading.

Q: How is the correct FMD72 configuration determined?

A: Configuration and sensor sizing are completed using Endress+Hauser Applicator software. It performs electronic DP calculations based on vessel dimensions and operating parameters.

Q: Can the FMD72 withstand high overpressure events?

A: Yes. The sensor cells tolerate up to 160 bar (2400 psi) overload and can operate down to 10 mbar absolute vacuum, protecting against typical process pressure excursions.

Q: What optional extras are available?

A: A four-line local digital display for on-site readings, plus a choice between aluminum or stainless steel housing to suit site environmental conditions.

 

Send us the complete FMD72 type code of your required configuration. We will verify the model selection and send you a formal quotation.

Kindly note: We can only quote based on the full ordering code or transmitter nameplate details. We cannot generate a model code or perform technical selection from P&ID tags or general process descriptions.

 

 

 

Contact now

 

 

 

 

Hot Tags: deltabar fmd72 electronic differential pressure transmitter, China deltabar fmd72 electronic differential pressure transmitter manufacturers, suppliers, factory, Coplanar Pressure Transmitter, In line Pressure Transmitter, pressure measurement, Submersible Pressure Transmitter, submersible transmitter, submersible water level transmitter

Send Inquiry