Guided Wave Radar Level Sensor Cable Type

Guided Wave Radar Level Sensor Cable Type
Details:
Precision Redefined. Measure liquids, solids, and interfaces with ±3mm accuracy, even in the most demanding industrial environments – engineered for excellence in chemical, oil & gas, and food & beverage applications.
Send Inquiry
Introduction
Technical Data
Features
Product Applications

Product Guarantees       FAQ

Introduction

 

The Guided Wave Radar Level Sensor Cable Type (XYRD9010-GWR) is a cutting-edge measurement solution designed for accurate and reliable level monitoring of liquids, bulk solids, and liquid interfaces across diverse industrial applications. Utilizing advanced guided wave radar technology, this sensor transmits high-frequency microwave pulses along a specialized cable probe, which reflect off the material surface and return to the sensor for precise calculation. The innovative cable design ensures signal transmission with minimal interference, even in challenging conditions characterized by dust, foam, or changing medium properties. This non-contact measurement technique eliminates wear and maintenance issues, delivering exceptional performance and long-term stability. With robust certifications (Exd IIC T6 Gb, Ex ia IIC T6 Ga) and IP67 protection, the sensor ensures safety and durability in hazardous environments. Its flexible installation cable antenna and adaptable process connections (thread/flange) make it ideal for space-limited installations, while wide temperature and pressure ranges extend its suitability to extreme processes. Choose the XYRD9010-GWR for unmatched accuracy (±3mm) and reliability in your critical level measurement applications.

 

Technical Data

 

Technical Excellence in Every Specification: Dive into the core metrics driving the XYRD9010-GWR's reliability in your toughest applications.

 

    XYRD9010-GWR

Applications

Liquids, Solid particle

Measuring range

30m, Min DK >1.6

Process connection

Thread/Flange

Process temperature

-40...180℃

Process pressure

-0.1...2.0MPa

Accuracy

±3mm

Resolution

±1mm

IP code

IP67

Frequency

100MHz...1.8GHz

Explosion-proof

Exd ⅡC T6 Gb, Ex iaⅡC T6 Ga

Output signal

4...20mA + HART (2-wire /4-wire)

RS485/Modbus

Wetted material

Rope probe: 304, 316

Housing material

Aluminium alloy+Anti-corrosion metal powder coating, stainless steel

Ambient temperature

-40...80℃

Electrical interface

M20*1.5/ 1/2NPT

Features

It is suitable for small spaces for its compact and flexible installation cable antenna. The instrument adapts to different industrial standard interfaces for various optional thread and flange.

 

Why Choose the XYRD9010-GWR?

  • Unparalleled Reliability: Proven performance in sticky, dusty, or turbulent media environments.
  • Cost-Effective Solution: Reduced installation complexity and long-term stability lower total ownership costs.
  • Global Compliance: Meets stringent international safety and performance standards (IECEx, ATEX).
  • Expert Support: Backed by technical consulting and customization services to meet unique application needs.

Contact Us Today to discuss your specific requirements or request a personalized quote. Our team is ready to help you optimize your level measurement processes.

 

Contact now

 

 

Features

 

  • Contactless & Reliable Measurement

Utilizes guided wave radar technology for precise level detection of liquids, powders, and granular solids, eliminating mechanical wear and maintenance.

  • Adaptable Cable Probe Design

Flexible cable antenna enables installation in confined spaces and complex vessel geometries, reducing installation costs and enhancing measurement flexibility.

  • Hazardous Area Certification

Certified for Zone 1/2 areas (Exd IIC T6 Gb) and Zone 0/1 (Ex ia IIC T6 Ga), ensuring safe operation in explosive environments common to oil & gas, chemical, and pharmaceutical industries.

  • Industry-Leading Accuracy & Resolution

Delivers ±3mm accuracy and ±1mm resolution, ensuring precise measurement data for critical process control and inventory management.

  • Rugged Build for Harsh Conditions

IP67 ingress protection, operating temperatures from -40 to 180°C, and pressures up to 2.0MPa, making it suitable for outdoor installations, extreme temperatures, and pressurized vessels.

  • Versatile Signal Output & Integration

Supports 4-20mA + HART (2-wire/4-wire) and RS485/Modbus protocols, facilitating seamless integration with DCS/PLC systems for real-time monitoring and advanced diagnostics.

  • Corrosion-Resistant Materials

Wetted parts made of 304/316 stainless steel ensure durability in corrosive media, while the housing features aluminum alloy with anti-corrosion coating for long-term reliability.

  • Wide Process Compatibility

Thread (M20*1.5, 1/2NPT) and flange options simplify installation across various tank types and industrial standards.

  • Low-Maintenance Design

Self-cleaning cable probe resists material buildup, reducing downtime and maintenance requirements.

  • Intuitive Configuration

User-friendly interface allows easy setup and calibration, minimizing commissioning time.

Product Applications

 

Where Challenges Arise, Accuracy Thrives: Industries & Scenarios Where the XYRD9010-GWR Delivers Unmatched Performance"

The Guided Wave Radar Level Sensor Cable Type is engineered to excel in demanding environments and specialized applications, making it ideal for:

1.Chemical & Petrochemical Processing

Measure corrosive liquids (e.g., acids, solvents) in storage tanks or reactors with aggressive media.

Monitor liquid interfaces in separation vessels (e.g., oil-water separators).

2.Food & Beverage Production

Ensure precise inventory control of viscous liquids (e.g., syrups, sauces) in small-diameter tanks.

Detect levels of powders or granules (e.g., sugar, flour) in deep silos with complex geometries.

3.Pharmaceutical & Biotech

Maintain sterile conditions and comply with GMP requirements for sensitive liquids or powders.

Handle hygienic processes with CIP/SIP-compatible materials (optional).

4.Water & Wastewater Treatment

Measure levels in open channels, clarifiers, or digesters with foam or sludge presence.

Monitor corrosive chemicals (e.g., chlorine) in storage tanks.

5.Power & Energy

Track fuel oils or coolant levels in boilers or heat exchangers operating at high temperatures (-40...180℃).

Ensure reliable measurements in fly ash silos with dusty environments.

 

Key Application Advantages:

  • Complex Geometries: Flexible cable probe adapts to narrow pipes, bypass legs, or vessels with internal obstacles.
  • Harsh Conditions: Operates reliably in extreme temperatures (-40...180℃), pressures (-0.1...2.0MPa), and explosive atmospheres (Exd/Exia certifications).
  • Interface Detection: Differentiate between two immiscible liquids (e.g., oil and water) for critical process control.
  • Industry 4.0 Readiness: HART or Modbus/RS485 outputs for seamless integration into DCS or SCADA systems.

 

Product Guarantees

 

Confidence in Every Measurement: Our Commitments to Quality, Reliability, & Support"

We back the XYRD9010-GWR with industry-leading guarantees to ensure your investment delivers long-term value:

1.Quality Assurance

  • ISO-Certified Manufacturing: Built to strict international quality standards.
  • 100% Factory Testing: Every unit undergoes calibration and functional tests for accuracy and reliability.

2.Performance Guarantee

  • 1-Year Warranty: Covers defects in materials and workmanship under normal operation.
  • ±3mm Accuracy Guarantee: Meets or exceeds specified tolerances across the full measurement range.

3.Safety & Compliance

  • Global Approvals: Certified for hazardous areas (Exd ⅡC T6 Gb, Ex iaⅡC T6 Ga) and IP67 protection.
  • Material Assurance: Wetted parts made from corrosion-resistant 304/316 stainless steel.

4.Expert Support

  • Lifetime Technical Assistance: Dedicated engineering team available for installation guidance, troubleshooting, and customizations.
  • 24/48-Hour Response Time: Critical inquiries prioritized within 1 business day.

5.Service Commitments

  • On-site Commissioning: Optional service for complex installations.
  • Calibration & Validation: Periodic recalibration services to maintain measurement integrity.

`**xyrd9010-gwr_ecm-emc-european-certification**`

`**xyrd9010-gwr_ecm-emc-european-certification**`

xyrd9010-gwr_clex-explosion-proof-hazardous-area-cn

 

FAQ

 

Q1: Can the cable probe be installed in tanks with internal obstructions (e.g., agitators or heating coils)?

A: Yes. The guided wave radar technology ensures the signal travels along the cable, minimizing interference from obstacles. The flexible probe can be routed around internal structures, maintaining measurement accuracy.

Q2: Is this sensor suitable for applications with low dielectric constant (Dk < 1.6) media?

A: Yes. The XYRD9010-GWR requires a minimum Dk of 1.6, making it suitable for many challenging media. Contact us to confirm compatibility or discuss custom solutions for ultra-low Dk applications.

Q3: How often does the sensor require recalibration?

A: Under normal operating conditions, the sensor is designed for long-term stability and typically requires recalibration every 2–3 years. However, this may vary based on process aggressiveness or regulatory requirements.

Q4: Can the sensor measure both liquids and solids with the same unit?

A: Yes. The cable type design allows measurement of liquids, bulk solids (e.g., powders, granules), and liquid interfaces. Adjustments may be required for different media properties-our team can assist with configuration.

Q5: What communication protocols are supported, and can I integrate it with my PLC/DCS?

A: The sensor supports 4-20mA + HART (2-wire/4-wire) and RS485/Modbus. It is compatible with most PLC/DCS systems. For specific integration questions, contact our engineering team.

Q6: Does the sensor require special maintenance in corrosive environments?

A: No. The wetted parts are made from 304/316 stainless steel, and the housing is IP67-rated with aluminum alloy or stainless steel options. Routine inspections are recommended but no special maintenance is required.

Q7: How is the sensor protected in explosive atmospheres?

A: The XYRD9010-GWR is certified Exd ⅡC T6 Gb (flameproof) and Ex iaⅡC T6 Ga (intrinsically safe) for Zone 1 and 2 hazardous areas. Ensure installation complies with local safety codes.

Q8: Can I install the sensor in outdoor environments with extreme temperatures (-40℃ to 80℃)?

A: Yes. The sensor's operating range covers -40...180℃ (process temperature) and -40...80℃ (ambient temperature). The housing and cable materials are designed for these conditions.

 

 

Hot Tags: Guided Wave Radar Level Sensor Cable Type, China Guided Wave Radar Level Sensor Cable Type manufacturers, suppliers, factory, 80GHz Radar Level Sensor for Corrosive Liquids, radar level sensor, Guided Wave Coaxial Tube Radar Level Sensor, Guided Wave Radar Level Sensor, 80GHz Radar Level Sensor for Basic Applications, 26GHz Radar Level Sensor for Basic Applications

Send Inquiry